Ask Question
9 May, 18:17

Consider a 1000-W iron whose base plate is made of 0.5-cm-thick aluminum alloy 2024-T6 (rho = 2770 kg/m3 and cp = 875 J/kg·°C). The base plate has a surface area of 0.03 m2. Initially, the iron is in thermal equilibrium with the ambient air at 22°C. Assuming 90 percent of the heat generated in the resistance wires is transferred to the plate, determine the minimum time needed for the plate temperature to reach 220°C.

+4
Answers (1)
  1. 9 May, 19:35
    0
    Answer: 79.98sec

    Explanation:

    Power received by plate = 0.9x1000

    = 900W

    Volume of metal = area x thickness

    V = 0.5x10^-2 x 0.03 = 1.5x10^-4m3

    Mass of metal = density x volume

    = 2770kg/m3 x 1.5x10^-4 = 0.4155kg

    Electrical heat energy = power x time = mass x specific heat capacity (Cp) x temperature change

    900 x t = 0.4155 x 875 x (220-22)

    900t = 71985.375

    t = 79.98s
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “Consider a 1000-W iron whose base plate is made of 0.5-cm-thick aluminum alloy 2024-T6 (rho = 2770 kg/m3 and cp = 875 J/kg·°C). The base ...” in 📙 Engineering if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.
Search for Other Answers