Ask Question
12 October, 08:30

A 350 m^3 retention pond that holds rainwater from a shopping mall is empty at the beginning of a rainstorm. The flow rate out of the retention pond must be restricted to 320 L/min to prevent downstream flooding from a 6-hour storm. What is the maximum flow rate (in L/min) into the pond from a 6-hr storm that will not flood it? a. 5,860 L/min b. 321 L/min c. 1.290 L/min d. 7.750 L/min

+1
Answers (1)
  1. 12 October, 11:59
    0
    correct option is c. 1.290 L/min

    Explanation:

    given data

    retention volume = 350 m³

    flow rate out = 320 L/min

    time = 6 hour

    to find out

    maximum flow rate (x)

    solution

    we apply here Mass rate of accumulation formula that is

    Mass rate of accumulation = mass rate of input - mass rate of output ... 1

    350 * 1000 L/m³ = x * (6hr * 60min) - (320 L * 6 hr * 60 min)

    3.5 * 10³ + 4.65 * 10³ = x * 360

    x = 1290 L/min

    so correct option is c. 1.290 L/min
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “A 350 m^3 retention pond that holds rainwater from a shopping mall is empty at the beginning of a rainstorm. The flow rate out of the ...” in 📙 Engineering if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.