Pressurized steam at 400 K flows through a long, thin-walled pipe of 0.6-m diameter. The pipe is enclosed in a concrete (stone mix) casing that is of square cross section and 1.75 m on a side. The axis of the pipe is centered in the casing, and the outer surfaces of the casing are maintained at 300 K. What is the rate of heat loss per unit length of pipe, in W/m

+2
Answers (1)
  1. 28 December, 19:53
    0
    Rate of heat loss per unit length of pipe, q' = 767.01 W/m

    Explanation:

    Let q' be the Rate of heat loss per unit length

    Let q be the Rate of heat loss

    q' = q/L

    Where L is the length of the pipe

    Diameter, D = 0.6m

    The rate of heat loss q is given by the formula: q = Sk (T₂ - T₁)

    Where k is the thermal conductivity of the concrete at 300 K

    k = 1.4 Wb/m-K (at 300K)

    And S is the shape factor given by the formula:

    S = 2πL / ln (1.08w/D)

    S = (2π*L) / ln (1.08*1.75/0.6))

    S = (2π*L) / 1.147

    S = 5.48 L

    q = 5.48L*1.4 (400-300)

    q = 767.01 L

    q' = q/L

    q' = 767.01L/L

    q' = 767.01 W/m
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “Pressurized steam at 400 K flows through a long, thin-walled pipe of 0.6-m diameter. The pipe is enclosed in a concrete (stone mix) casing ...” in 📙 Engineering if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.