A composite plane wall consists of a Li = 50 mm thick layer of insulation (ki = 0.05 W/m·K) and a Ls = 25 mm thick layer of siding (ks = 0.10 W/m·K). The inner temperature of the insulation is 25oC. The outer temperature of the siding is - 10oC. Steady state conditions apply. Determine the temperature at the interface between the two layers, in oC, and the rate of heat transfer through the wall, in W per m2 of surface area.

+3
Answers (1)
  1. 27 May, 22:09
    0
    Let the temperature of interface be θ

    In steady state, rate of heat flow in the two mediums will be equal.

    Rate of heat flow in thick layer

    =.05 A (25 - θ) / 50 x 10⁻³

    Rate of heat flow in thin layer

    .1 x A (θ + 10) / 25 X 10⁻³

    .05 A (25 - θ) / 50 x 10⁻³ =.1 x A (θ + 10) / 25 X 10⁻³

    .05 X (25 - θ) / 2 = 0.1 (θ + 10)

    05 X (25 - θ) =.2 (θ + 10)

    1.25 -.05 θ =.2 θ + 2

    - 0.75 =.25 θ

    θ = - 3 degree only
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “A composite plane wall consists of a Li = 50 mm thick layer of insulation (ki = 0.05 W/m·K) and a Ls = 25 mm thick layer of siding (ks = ...” in 📙 Physics if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.