Ask Question
23 March, 00:29

If a student did not remove all of the bubbles from inside the buret before reading the initial volume and beginning the titration, will this cause the calculated concentration of the hydrochloric acid determined from that trial to be higher or lower than the actual concentration? explain your answer in complete sentences.

+2
Answers (1)
  1. 23 March, 02:06
    0
    Hello!

    If there's an air bubble inside the buret, and the bubble escapes the buret during the titration the initial volume lecture (Vi) would be lower (closer to 0) than the actual one, and the recorded consumed volume (ΔV=Vf-Vi) would be higher than the actual one and thus the calculated concentration of the hydrochloric acid would be higher than the real one.

    Have a nice day!
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “If a student did not remove all of the bubbles from inside the buret before reading the initial volume and beginning the titration, will ...” in 📙 Chemistry if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.
Search for Other Answers