Pressurized steam at 450 K flows through a long, thin-walled pipe of 0.5-m diameter. The pipe is enclosed in a concrete casing that is of square cross section and 1.5 m on a side. The axis of the pipe is centered in the casing, and the outer surfaces of the casing are maintained at 300 K. What is the heat loss per unit length of pipe

+5
Answers (1)
  1. 7 September, 10:02
    0
    Heat loss per unit length of pipe = q' = 1363.47 W/m

    Explanation:

    Heat loss per unit length would be in terms of W/m.

    Assumptions:

    • steady-state conditions

    • negligible steam side convection resistance, pipe wall resistance and contact resistance (T1 = 450 K)

    • constant properties

    The thermal conductivity for concrete must be found.

    Referring to the table of thermal conductivity of some common materials, the value for stone concrete will be used, which is 1.7.

    The heat rate can be expressed as:

    q = SkΔT₁₋₂ = Sk (T₁ - T₂)

    The proper shape factor is needed for the solution and is found from the list of shape factors. The shape factor must be for a circular cylinder of length L centered in a square solid of equal length and is:

    S = 2πL : [ln (1.08w/D) ]

    Then,

    q' = q : L

    The full equation is:

    q' = 2πk (T₁ - T₂) : [ln (1.08w/D) ]

    Substituting known values:

    q' = 2π (1.7 W/mK) * (450 K - 300 K) : [ln [1.08 (1.5 m) / 0.5 m] ]

    q' = 1363.47 W/m
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “Pressurized steam at 450 K flows through a long, thin-walled pipe of 0.5-m diameter. The pipe is enclosed in a concrete casing that is of ...” in 📙 Engineering if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.