Ask Question
18 November, 19:14

An air compressor compresses 6 L of air at 120 kPa and 22°C to 1000 kPa and 400°C. Determine the flow work, in kJ/kg, required by the compressor. The gas constant of air is R = 0.287 kPa·m3/kg·K. The flow work required by the compressor is

+2
Answers (1)
  1. 18 November, 23:11
    0
    The work flow required by the compressor = 100.67Kj/kg

    Explanation:

    The solution to this question is obtained from the energy balance where the initial and final specific internal energies and enthalpies are taken from A-17 table from the given temperatures using interpolation.

    The work flow can be determined using the equation:

    M1h1 + W = Mh2

    U1 + P1alph1 + ◇U + Workflow = U2 + P2alpha2

    Workflow = P2alpha2 - P1alpha1

    Workflow = (h2 - U2) - (h1 - U1)

    Workflow = (684.344 - 491.153) - (322.483 - 229.964)

    Workflow = (193.191 - 92.519) Kj/kg

    Workflow = 100.672Kj/kg
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “An air compressor compresses 6 L of air at 120 kPa and 22°C to 1000 kPa and 400°C. Determine the flow work, in kJ/kg, required by the ...” in 📙 Physics if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.
Search for Other Answers