10 June, 04:11

Two Carnot air conditioners, A and B, are removing heat from different rooms. The outside temperature is the same for both rooms, 313 K. The room serviced by unit A is kept at a temperature of 294 K, while the room serviced by unit B is kept at 302 K. The heat removed from either room is 4510 J. For both units, find (a), (b) the magnitude of the work required and (c), (d) the magnitude of the heat deposited outside for A and B conditioners respectively.

+3
Answers (1)
  1. 10 June, 06:29
    0
    Coefficient of performance of cooling apparatus

    = Heat output / energy input

    = T₁ / T₁ - T₂

    Where T₁ = Temp of hot end and T₂ = cold end

    For A

    Heat output / energy input = 313 / (313 - 294)

    = (Heat withdrawn + energy input) / energy input = 313 / 19

    1 + Heat withdrawn / energy input = 313 / 19

    Heat withdrawn / energy input = 294 / 19

    energy input = 19/294 x Heat withdrawn

    = 19/294 x 4510

    = 291.46 J

    Heat deposited = 291.46 + 4510 = 4801.46 J

    Similarly for B

    energy input = 313-302 / 302 x Heat withdrawn

    = 11 / 302 X 4510

    = 164.27

    Heat deposited = 164.27 + 4510 = 4674.27 J
Know the Answer?
Not Sure About the Answer?
Get an answer to your question ✅ “Two Carnot air conditioners, A and B, are removing heat from different rooms. The outside temperature is the same for both rooms, 313 K. ...” in 📙 Physics if there is no answer or all answers are wrong, use a search bar and try to find the answer among similar questions.